RAT Support Forum 

Indication and altering range
Posted by: janice parikh ()
Date: 31 October, 2006 09:17AM

We have a patient discharged from hospital on lifelong warfarin for the condition of Eisenmenger's Syndrome with an INR recommended range of 1.8 --2.5.
I am uncertain how to alter RAT to include this indication and change the range from those available in the picking list.
Grateful for guidance. Janice

Re: Indication and altering range
Posted by: Colm Rafferty ()
Date: 31 October, 2006 06:03PM

Dear Janice,
RAT does not have a range for this indication.
You could use either 1.5-2.5 or 2.0-2.5
The wider the range the easier it is to manage.

RAT has all the recommended conditions and associated ranges as per the British Society for Haematology (http://www.b-s-h.org.uk)
[www.bcshguidelines.com]
I am not aware that Eisenmenger's Syndrome is one of them.


Colm Rafferty

    Please note RAT should only be used by health professionals familiar with warfarin management