Date: 31 October, 2006 09:17AM We have a patient discharged from hospital on lifelong warfarin for the condition of Eisenmenger's Syndrome with an INR recommended range of 1.8 --2.5.
I am uncertain how to alter RAT to include this indication and change the range from those available in the picking list. Grateful for guidance. Janice Re: Indication and altering range
Posted by:
Colm Rafferty
()
Date: 31 October, 2006 06:03PM Dear Janice,
RAT does not have a range for this indication. You could use either 1.5-2.5 or 2.0-2.5 The wider the range the easier it is to manage. RAT has all the recommended conditions and associated ranges as per the British Society for Haematology (http://www.b-s-h.org.uk) [www.bcshguidelines.com] I am not aware that Eisenmenger's Syndrome is one of them. Colm Rafferty
|
|